# Ranking inside one potency window

Registered at `benchmarks/preregistered/2026-10-16-within-series.md` before the
comparison was run. Interim, 31 targets of a possible 123. The run continues as
the ligand baseline fetches the remaining ChEMBL pools.

## The question

A medicinal chemist with forty analogues of one scaffold and potencies spanning
a log and a half wants them ranked. Our headline of 0.607 is measured on
held-out sets spanning a median of 4.15 log units with no two compounds sharing
a Murcko scaffold, so it has never answered that. This measures both arms again
with the potency range held fixed.

## What we measured

For each target, take the median measured potency of its held-out compounds and
keep the compounds within 0.75 log of it. That is a 1.5 log window. Both arms
predict the same compounds. The structure arm is the prediction already on disk
from the corpus run, with no new folding. The ligand arm is a random forest on
ECFP4 trained on the target's ChEMBL pool with the held-out compounds removed,
which is the same model and the same code as the registered ligand baseline.

Thirty one targets have 8 or more compounds inside the window and a pool the
ligand arm can train on. The median window holds 10 compounds.

## Final, 16 October 2026

The run is complete. **115 targets scored and 8 excluded.** Six of the eight
carry fewer than eight compounds with both a prediction and a measurement,
which is the floor the registration set. Two have no ChEMBL pool, and they are
the same two the ligand baseline excluded for the same reason.

**Primary outcome, 1.5 log window, 84 qualifying targets and 953 compounds.**
Structure median 0.271, ligand median 0.375. Mean difference **minus 0.1436,
95 percent interval minus 0.2265 to minus 0.0625**, which excludes zero. The
structure arm is ahead on 33 of 84.

**Secondary, 1.0 log window, 44 qualifying targets and 458 compounds.**
Structure median 0.143, ligand median 0.387, mean difference minus 0.2375 with
an interval of minus 0.3415 to minus 0.1347.

**Sample size control.** Against random subsets of the same size drawn with no
restriction on potency, the window costs **0.264** in the 1.5 log case,
interval minus 0.327 to minus 0.200, and 0.331 in the 1.0 log case. Narrowing
the range costs more than losing the compounds does.

**Ground truth noise.** Two hundred and eighty three of the 953 compounds
inside the 1.5 log windows, **30 percent**, have their own ChEMBL assays
disagreeing with each other by more than our prediction error on that target.

### How the reading moved as the run grew

Minus 0.0856 at 31 qualifying targets, minus 0.0627 at 35, minus 0.0516 at 38,
minus 0.1118 at 68, minus 0.1436 at 84. The estimate moved away from zero and
the interval tightened past it, so the early readings were the optimistic ones
and waiting was the right call.

### What the decision rule says

The registration fixed it: an interval containing zero or lying below it means
we publish that inside a potency window the structure arm does not rank better
than a fingerprint model, put that sentence on the front page beside the
headline, and name the within-window task as something the platform does not
do. That is published and the sentence on the explainer is computed from the
interval rather than typed beside it.

### What it does not cover

On 14 published congeneric series the two arms cannot be told apart, 0.660
against 0.567 with an interval containing zero. Those sets span 0.75 log units
and come from one assay in one paper. The windows here are cut from ChEMBL and
pool IC50 and Ki across laboratories. We tested whether width explains the
difference and it does not, which is argued in
`benchmarks/results/2026-10-16-congeneric-series.md`.


## The interim readings, kept because they were published

The sections below were written while the run was going and are
superseded by the final numbers above. They are kept rather than
replaced, because a project that quietly overwrites what it said last
week has no corrections record worth anything.

## The primary outcome

Structure minus ligand, inside the window, paired over targets.

**Mean difference minus 0.0856, 95 percent bootstrap interval minus 0.2195 to
plus 0.0478.** The interval contains zero. The structure arm is ahead on 13 of
31 targets.

Inside a potency window we cannot tell the two arms apart. Median Spearman is
0.318 for the structure arm and 0.336 for the ligand arm.

## What the window costs, and what it costs the other arm

Both arms lose accuracy when the potency range narrows. The structure arm falls
from 0.474 to 0.318 in median Spearman, a paired mean change of minus 0.203
with an interval of minus 0.311 to minus 0.093. The ligand arm falls further,
from 0.673 to 0.336, a paired mean change of minus 0.292 with an interval of
minus 0.388 to minus 0.195.

So the structure arm loses less than the fingerprint model does. The difference
between the two losses is plus 0.089 with an interval of minus 0.021 to plus
0.199, which contains zero, so we cannot establish that the structure arm is
more robust to a narrow window. We can say that its position relative to the
fingerprint model improves inside one.

On the full held-out sets of these same 31 targets the ligand arm is ahead by
0.174 with an interval of minus 0.287 to minus 0.067, which excludes zero.
Inside the window that advantage is gone.

## The sample size control

A narrow window holds fewer compounds, and fewer compounds alone moves a rank
correlation. For each target we drew 200 random subsets of the full held-out
set, each the same size as that target's window subset, with no restriction on
potency range, and averaged the structure arm Spearman across them. Median
0.449, against 0.318 inside the window. The paired difference is minus 0.183
with an interval of minus 0.290 to minus 0.075.

Narrowing the range costs 0.18 Spearman beyond what losing compounds costs.
Range restriction attenuates a rank correlation arithmetically for any
predictor. The ligand arm loses more than the structure arm does over the same
restriction. So 0.18 is the size of the effect on our predictions, and part of
it is arithmetic rather than the model.

## Fold error inside the window

Structure 3.0x, ligand 3.11x, both median absolute. The headline number on the
full sets is 4.6x, so the error is smaller inside the window while the ranking
is worse. A narrow window compresses the quantity being predicted, which makes
the error smaller and the order harder.

## The ground truth disagrees with itself

One hundred and ten of the 336 compounds inside the windows, 33 percent, have
their own ChEMBL assays disagreeing with each other by more than the structure
arm's median fold error on that target. A third of the data cannot distinguish
our prediction from the measurement it is scored against.

## The tighter window

A 1.0 log window qualifies 15 targets. Structure median 0.143, ligand median
0.370, mean difference minus 0.231 with an interval of minus 0.401 to minus
0.058, which excludes zero and favours the ligand arm. This was registered as a
secondary outcome and it rests on 15 targets. It is reported and it does not
decide anything.

## Status, as it stood during the run

Interim. That line stayed on this file until the run finished, and the
readings it covered are above.

## What this does not cover

The window is cut around each target's median potency, not around one scaffold,
because the held-out sets contain no scaffold pairs to cut around. It holds
potency range fixed and leaves chemical diversity wide. A congeneric series is
narrow in both. `benchmarks/results/fep15-control.json` holds 14 sets that are
narrow in both, where the mean difference is plus 0.033 with an interval of
minus 0.093 to plus 0.155 and the ligand arm is ahead on 6 of 14.

## Files

- `benchmarks/results/within-series.jsonl`, one row per target with both arms,
  both windows, the sample size control and the assay spread count.
- `scripts/within_series.py`, the run.